dc.contributor | Vall d'Hebron Barcelona Hospital Campus |
dc.contributor.author | Teixido Tura, Gisela |
dc.contributor.author | Granato, Chiara |
dc.contributor.author | De Carvalho Negrao Valente, Filipa Xavier |
dc.contributor.author | Galián Gay, Laura |
dc.contributor.author | Gutierrez García-Moreno, Laura |
dc.contributor.author | González Alujas, Teresa |
dc.contributor.author | Sao Aviles, Augusto Cesar |
dc.contributor.author | Evangelista Masip, Artur |
dc.contributor.author | Guala, Andrea |
dc.contributor.author | Dux-Santoy Hurtado, Lydia |
dc.contributor.author | Rodríguez Palomares, Jose Fernando |
dc.contributor.author | Ruiz Muñoz, Aroa |
dc.date.accessioned | 2020-07-31T11:58:45Z |
dc.date.available | 2020-07-31T11:58:45Z |
dc.date.issued | 2019-10-14 |
dc.identifier.citation | Guala A, Teixido-Tura G, Dux-Santoy L, Granato C, Ruiz-Munõz A, Valente F, et al. Decreased rotational flow and circumferential wall shear stress as early markers of descending aorta dilation in Marfan syndrome: A 4D flow CMR study. J Cardiovasc Magn Reson [Internet]. 2019 Oct 14;21(1):63. |
dc.identifier.issn | 1097-6647 |
dc.identifier.uri | https://hdl.handle.net/11351/5125 |
dc.description | Síndrome de Marfan; Flux en 4D CMR; Flux helicoïdal |
dc.description.sponsorship | This study has been funded by Instituto de Salud Carlos III through the project PI14/0106 (co-founded by European Regional Development Fund), La Marato de TV3 (project number 20151330), by Ministerio de Economia y Competitividad through Retos-Colaboracion 2016 (RTC-2016-5152-1). Guala A. has received funding from the European Union Seventh Framework Programme FP7/People under grant agreement no 267128. |
dc.language.iso | eng |
dc.publisher | BMJ Publishing Group |
dc.relation.ispartofseries | Journal of Cardiovascular Magnetic Resonance;21(1) |
dc.rights | Attribution 4.0 International |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ |
dc.source | Scientia |
dc.subject | Cromosoma humà 15 - Anomalies |
dc.subject | Imatgeria per ressonància magnètica |
dc.subject | Estudi de casos |
dc.subject.mesh | Marfan Syndrome |
dc.subject.mesh | Magnetic Resonance Imaging |
dc.subject.mesh | Case-Control Studies |
dc.title | Decreased rotational flow and circumferential wall shear stress as early markers of descending aorta dilation in Marfan syndrome: a 4D flow CMR study |
dc.type | info:eu-repo/semantics/article |
dc.identifier.doi | 10.1186/s12968-019-0572-1 |
dc.subject.decs | síndrome de Marfan |
dc.subject.decs | imagen por resonancia magnética |
dc.subject.decs | estudios de casos y controles |
dc.relation.publishversion | https://jcmr-online.biomedcentral.com/articles/10.1186/s12968-019-0572-1 |
dc.type.version | info:eu-repo/semantics/publishedVersion |
dc.audience | Professionals |
dc.contributor.authoraffiliation | [Guala A, Teixido-Tura G, Dux-Santoy L, Granato C, Ruiz-Muñoz A, Valente F, Galian-Gay L, Gutiérrez L, González-Alujas T, Sao Avilés A, Evangelista A, Rodriguez-Palomares J] Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Centro de Investigación Biomédica en Red de Enfermedades Cardiovaculares (CIBER-CV), Madrid, Spain. Grup de Recerca en Malalties Cardiovasculars, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Universitat Autònoma de Barcelona, Barcelona, Spain |
dc.identifier.pmid | 31607265 |
dc.identifier.wos | 000501597900001 |
dc.relation.projectid | info:eu-repo/grantAgreement/ES/PE2013-2016/PI14%2F0106 |
dc.relation.projectid | info:eu-repo/grantAgreement/EC/FP7/267128 |
dc.rights.accessrights | info:eu-repo/semantics/openAccess |