Show simple item record

 
dc.contributorVall d'Hebron Barcelona Hospital Campus
dc.contributor.authorSiliato, María Sol
dc.contributor.authorMoradi, Mehrdad
dc.contributor.authorPALMER CAMINO, NEISER EDUARDO
dc.contributor.authorVigil-Escalera, Carlota
dc.contributor.authorRodríguez Lecoq, Rafael
dc.date.accessioned2023-08-30T09:42:55Z
dc.date.available2023-08-30T09:42:55Z
dc.date.issued2023-06-01
dc.identifier.citationSiliato MS, Moradi M, Palmer N, Vigil-Escalera López C, Rodríguez R. Extracción de electrodos de marcapasos no infectados con LASER: una técnica segura. Cirugía Cardiovasc. 2023 Jun 1;30(4):265–7.
dc.identifier.issn1134-0096
dc.identifier.urihttps://hdl.handle.net/11351/10176
dc.descriptionExtraction of cardiac stimulation devices; Laser technique; Non-infected devices
dc.description.abstractTransvenous lead extraction is indicated in patients with infection of the cardiac stimulation devices according to the guidelines. However, in those patients who have lead dysfunction but not infection, lead extraction is controversial and risks and benefices should be individually assessed. We present the case of a 33 years old male patient with the only medical history of an early sinusal dysfunction due to a genetic variant. At the age of 14 years old, because of a malignant syncope, an electrophysiological study was performed and a DDDR double chamber pacemaker was implanted. At the age of 32 due to device dysfunction a new pacemaker was implanted and the former leads were abandoned. One year later a new dysfunction of the device could be seen. The extraction of all leads and implantation of a new double chamber pacemaker was indicated. The complete extraction of all leads was performed with a combination of LASER technique and mechanical sheath without problems. A new device was implanted. The patient had an uneventful postoperative period and could be discharged home the day after surgery.
dc.language.isospa
dc.publisherElsevier
dc.relation.ispartofseriesCirugía Cardiovascular;30(4)
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceScientia
dc.subjectEstimulació elèctrica
dc.subjectMarcapassos
dc.subjectCor - Cirurgia per làser
dc.subject.meshCardiac Pacing, Artificial
dc.subject.meshDevice Removal
dc.subject.meshLaser Therapy
dc.titleExtracción de electrodos de marcapasos no infectados con LASER: una técnica segura
dc.title.alternativeNon-infected pacemaker lead LASER extraction: A safe technique
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1016/j.circv.2022.12.036
dc.subject.decsestimulación cardíaca artificial
dc.subject.decsextracción de implantes
dc.subject.decstratamiento con láser
dc.relation.publishversionhttps://doi.org/10.1016/j.circv.2022.12.036
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.audienceProfessionals
dc.contributor.organismesInstitut Català de la Salut
dc.contributor.authoraffiliation[Siliato MS, Moradi M, Palmer N, Vigil-Escalera López C, Rodríguez R] Servei de Cirurgia Cardíaca, Vall d’Hebron Hospital Universitari, Barcelona, Spain
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record