Torna al Registre Simple

 
dc.contributorVall d'Hebron Barcelona Hospital Campus
dc.contributor.authorGarcía-Touchard, Arturo
dc.contributor.authorSabaté Tenas, Manel
dc.contributor.authorGonzalo, Nieves
dc.contributor.authorperal disdier, vicente
dc.contributor.authorVaquerizo, Beatriz
dc.contributor.authorRuiz-Salmeron, Rafael
dc.contributor.authorGarcía del Blanco, Bruno
dc.date.accessioned2023-11-17T13:42:09Z
dc.date.available2023-11-17T13:42:09Z
dc.date.issued2023-10-31
dc.identifier.citationGarcía-Touchard A, Sabaté M, Gonzalo N, Peral V, Vaquerizo B, Ruiz-Salmerón R, et al. Very long-term efficacy and safety of paclitaxel-eluting balloon after a bare-metal stent for the treatment of ST-elevation myocardial infarction: 8-year results of a randomized clinical trial (PEBSI study). Cardiovasc Diagn Ther. 2023 Oct 31;13(5):792–804.
dc.identifier.issn2223-3652
dc.identifier.urihttps://hdl.handle.net/11351/10623
dc.descriptionStents alliberadors de fàrmacs; Globus recoberts de fàrmacs; Infart de miocardi
dc.description.sponsorshipThis investigation has received the support of the Spanish Clinical Research Network (SCReN), financed by the ISCIII-Subdirección General de Evaluación y Fomento de la Investigación, under the project PT13/0002/0005 (Plan Estatal de I+D+I 2013-2016) and co-funded by the European Regional Development Fund (FEDER). An unrestricted research grant was received from Biotronik.
dc.language.isoeng
dc.publisherAME Publishing Company
dc.relation.ispartofseriesCardiovascular Diagnosis and Therapy;13(5)
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceScientia
dc.subjectAvaluació de resultats (Assistència sanitària)
dc.subjectInfart de miocardi - Tractament
dc.subjectPròtesis de Stent
dc.subjectMedicaments - Alliberament retardat
dc.subject.meshTreatment Outcome
dc.subject.meshMyocardial Infarction
dc.subject.mesh/drug therapy
dc.subject.meshDrug-Eluting Stents
dc.titleVery long-term efficacy and safety of paclitaxel-eluting balloon after a bare-metal stent for the treatment of ST-elevation myocardial infarction: 8-year results of a randomized clinical trial (PEBSI study)
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.21037/cdt-22-623
dc.subject.decsresultado del tratamiento
dc.subject.decsinfarto de miocardio
dc.subject.decs/farmacoterapia
dc.subject.decsstents liberadores de fármacos
dc.relation.publishversionhttp://dx.doi.org/10.21037/cdt-22-623
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.audienceProfessionals
dc.contributor.organismesInstitut Català de la Salut
dc.contributor.authoraffiliation[García-Touchard A] Department of Interventional Cardiology, Hospital Universitario Puerta De Hierro Majadahonda, Madrid, Spain. [Sabaté M] Department of Interventional Cardiology, Hospital Clinic i Provincial, Barcelona, Spain. [Gonzalo N] Department of Interventional Cardiology, Hospital Clínico San Carlos, Madrid, Spain. [Peral V] Department of Interventional Cardiology, Health Research Institute of the Balearic Islands (IdISBa), Hospital Universitari Son Espases, Palma de Mayorca, Spain. [Vaquerizo B] Department of Interventional Cardiology, Hospital Del Mar, Barcelona, Spain. [Ruiz-Salmerón R] Department of Interventional Cardiology, Hospital Virgen Macarena, Sevilla, Spain. [García Del Blanco B] Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain
dc.identifier.pmid37941845
dc.identifier.wos001087464600001
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess


Fitxers en aquest element

Portada del document

Aquest element apareix en la col·lecció o col·leccions següent(s)

Torna al Registre Simple