dc.date.issued2025-03
dc.identifier.citationOliver-Gutiérrez D, Segura-Duch G, Ávila-Marrón E, Arciniegas-Perasso CA, Duch-Tuesta S. Paul versus Baerveldt 350 glaucoma drainage implants: One-year comparative analysis. Indian J Ophthalmol. 2025 Mar;73(Suppl 2):S317-23.
dc.identifier.issn1998-3689
dc.identifier.urihttp://hdl.handle.net/11351/12944
dc.descriptionDrainage implants; Glaucoma
dc.description.abstractPurpose: This study aimed to evaluate and compare the effectiveness and safety of Paul glaucoma implant (PGI) and Baerveldt 350 glaucoma implant (BGI) over a 1-year follow-up period. Methods: This retrospective study was conducted in a private clinic. It compared 27 patients consecutively treated with the PGI to a historical cohort of 29 eyes that received the BGI prior to the introduction of the PGI between 2018 and 2023. Intervention: A new drainage device, the Paul implant, was placed in the anterior or posterior chamber of eyes with uncontrolled intraocular pressure (IOP). Main Outcome Measures: The main outcome measures were success rate, final mean IOP, IOP reduction percentage, medication reduction, and complications. Statistical analyses, including adjustments for confounders, were used to compare the performance of PGI and BGI over at least a 12-month period. Results: Significant reductions in IOP were observed in both groups (P < 0.001). At 1 year, no significant differences were found in mean IOP (BGI: 12.0 mmHg, SD 2.9; PGI: 11.2 mmHg, SD 6.0) or medication usage (P > 0.05). The failure rates were 7% for BGI and 18% for PGI, with complete success rates of 56% for BGI and 32% for PGI. Hypertensive phases occurred in 32% of the BGI cases and in 19% of the PGI cases. No significant differences in the complication rates or postoperative visual acuity were observed between the groups. Conclusion: PGI and BGI exhibited comparable efficacy and safety profiles after 1 year.
dc.language.isoeng
dc.publisherWolters Kluwer
dc.relation.ispartofseriesIndian Journal of Ophthalmology;73(Suppl 2)
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceScientia
dc.subjectAvaluació de resultats (Assistència sanitària)
dc.subjectGlaucoma - Cirurgia
dc.subjectLents intraoculars
dc.subjectPressió intraocular
dc.subject.meshTreatment Outcome
dc.subject.meshIntraocular Pressure
dc.subject.meshGlaucoma
dc.subject.mesh/surgery
dc.subject.meshGlaucoma Drainage Implants
dc.titlePaul versus Baerveldt 350 glaucoma drainage implants: One-year comparative analysis
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.4103/IJO.IJO_2595_24
dc.subject.decsresultado del tratamiento
dc.subject.decspresión intraocular
dc.subject.decsglaucoma
dc.subject.decs/cirugía
dc.subject.decsimplantes de drenaje del glaucoma
dc.relation.publishversionhttps://doi.org/10.4103/IJO.IJO_2595_24
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.audienceProfessionals
dc.contributor.organismesInstitut Català de la Salut
dc.contributor.authoraffiliation[Oliver-Gutiérrez D] VERTE_ICO Ophthalmology, Barcelona, Spain. Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Segura-Duch G] VERTE_ICO Ophthalmology, Barcelona, Spain. Centro de Oftalmología Barraquer, Institut Universitari Barraquer, Universitat Autònoma de Barcelona, Bellaterra, Spain. [Ávila-Marrón E, Arciniegas-Perasso CA, Duch-Tuesta S] VERTE_ICO Ophthalmology, Barcelona, Spain
dc.identifier.pmid39982092
dc.identifier.wos001432089000037
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record