Regresa al Registro Simple

 
dc.contributorVall d'Hebron Barcelona Hospital Campus
dc.contributor.authorAndrés Peiró, José Vicente
dc.contributor.authorPiedra Calle, Carlos Alberto
dc.contributor.authorTomás-Hernández, Jordi
dc.contributor.authorCorona, Pablo S.
dc.contributor.authorAmat, Carles
dc.contributor.authorTeixidor Serra, Jordi
dc.date.accessioned2025-05-21T12:55:12Z
dc.date.available2025-05-21T12:55:12Z
dc.date.issued2025-05
dc.identifier.citationAndrés-Peiró JV, Piedra-Calle CA, Tomàs-Hernández J, Corona PS, Amat C, Teixidor-Serra J. “Close to the tip, with little bone to grip”: stabilizing two periprosthetic proximal femur fractures above a distal femur megaprosthesis using a combination of DHS and 3.5 mm screws. Trauma Case Reports. 2025 May;57:101167.
dc.identifier.issn2352-6440
dc.identifier.urihttp://hdl.handle.net/11351/13116
dc.descriptionTornillo dinámico de cadera; Megaprótesis; Fractura periprotésica
dc.language.isoeng
dc.publisherElsevier
dc.relation.ispartofseriesTrauma Case Reports;57
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceScientia
dc.subjectOsteosíntesi
dc.subjectFèmur - Fractures
dc.subjectFèmur - Cirurgia
dc.subject.meshPeriprosthetic Fractures
dc.subject.mesh/surgery
dc.subject.meshHip Fractures
dc.subject.meshFracture Fixation, Internal
dc.subject.meshBone Screws
dc.title“Close to the tip, with little bone to grip”: stabilizing two periprosthetic proximal femur fractures above a distal femur megaprosthesis using a combination of DHS and 3.5 mm screws
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1016/j.tcr.2025.101167
dc.subject.decsfracturas periprotésicas
dc.subject.decs/cirugía
dc.subject.decsfracturas de cadera
dc.subject.decsfijación interna de fractura
dc.subject.decstornillos óseos
dc.relation.publishversionhttps://doi.org/10.1016/j.tcr.2025.101167
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.audienceProfessionals
dc.contributor.organismesInstitut Català de la Salut
dc.contributor.authoraffiliation[Andrés-Peiró JV, Corona PS, Teixidor-Serra J] Servei de Cirurgia Ortopèdica i Traumatologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Grup de Recerca en Cirurgia Reconstructiva de l’Aparell Locomotor, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Departament de Cirurgia, Universitat Autònoma de Barcelona, Bellaterra, Spain. [Piedra-Calle CA, Tomàs-Hernández J, Amat C] Servei de Cirurgia Ortopèdica i Traumatologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Grup de Recerca en Cirurgia Reconstructiva de l’Aparell Locomotor, Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain
dc.identifier.pmid40291411
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess


Ficheros en el ítem

Portada del documento

Este ítem aparece en la(s) siguiente(s) colección(ones)

Regresa al Registro Simple