Show simple item record

 
dc.contributorVall d'Hebron Barcelona Hospital Campus
dc.contributor.authorGomez Plaza, Daniel
dc.contributor.authorOliver-Gutierrez, David
dc.contributor.authorGarcia-Arumi, Claudia
dc.contributor.authorGarcia-Arumi, Jose
dc.date.accessioned2025-09-22T08:31:38Z
dc.date.available2025-09-22T08:31:38Z
dc.date.issued2025-06
dc.identifier.citationOliver-Gutierrez D, García-Arumí C, Gómez Plaza D, García-Arumí J. Surgical Technique: Viscodissection for Managing Funnel Retinal Detachments. J Clin Med. 2025 Jun;14(13):4394.
dc.identifier.issn2077-0383
dc.identifier.urihttp://hdl.handle.net/11351/13709
dc.descriptionFunnel-shaped retinal detachment; Viscodissection; Vitreoretinal surgery
dc.description.abstractPurpose: To evaluate and describe the efficacy and safety of viscodissection in managing complex funnel-shaped retinal detachments, minimizing trauma and facilitating safer perfluorocarbon liquid (PFCL) application. Methods: A retrospective case series of five patients with funnel-shaped retinal detachments: three due to perforating trauma and two from recurrent detachments. Initial visual acuities ranged from light perception to hand motion. Viscodissection was used to separate adhered retinal tissues in the funnel-shaped retinal detachment in a controlled, minimally traumatic manner, allowing funnel opening and PFCL application. Data collected included demographics, visual acuities, surgical details, and complications. Results: Viscodissection enabled successful funnel opening and PFCL use in all cases, with one instance of subretinal migration of PFCL. No retinal detachment recurrences occurred, but three patients required reoperation for new premacular proliferative vitreoretinopathy (PVR). Postoperative visual acuities improved in four patients (up to 20/100), while one remained at hand motion. Conclusions: Viscodissection is a promising technique for complex funnel-shaped retinal detachments, allowing non-traumatic tissue separation and improving visualization and safety during PFCL application. This approach may enhance surgical outcomes and reduce complications.
dc.language.isoeng
dc.publisherMDPI
dc.relation.ispartofseriesJournal of Clinical Medicine;14(13)
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceScientia
dc.subjectAvaluació de resultats (Assistència sanitària)
dc.subjectDespreniment de retina - Cirurgia
dc.subjectVitreoretinopatia proliferativa
dc.subject.meshTreatment Outcome
dc.subject.meshRetinal Detachment
dc.subject.mesh/surgery
dc.subject.meshOphthalmologic Surgical Procedures
dc.subject.meshVitreoretinopathy, Proliferative
dc.titleSurgical Technique: Viscodissection for Managing Funnel Retinal Detachments
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.3390/jcm14134394
dc.subject.decsresultado del tratamiento
dc.subject.decsdesprendimiento de retina
dc.subject.decs/cirugía
dc.subject.decsprocedimientos quirúrgicos oftalmológicos
dc.subject.decsvitreorretinopatía proliferativa
dc.relation.publishversionhttps://doi.org/10.3390/jcm14134394
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.audienceProfessionals
dc.contributor.organismesInstitut Català de la Salut
dc.contributor.authoraffiliation[Oliver-Gutierrez D] Servei d’Oftalmologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. [García-Arumí C, García-Arumí J] Servei d’Oftalmologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Department of Ophthalmology, Instituto de Microcirugía Ocular (IMO), Miranza, Barcelona, Spain. [Gómez Plaza D] Department of Ophthalmology, Instituto de Microcirugía Ocular (IMO), Miranza, Barcelona, Spain
dc.identifier.pmid40648767
dc.identifier.wos001526104800001
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record