Show simple item record

 
dc.contributorVall d'Hebron Barcelona Hospital Campus
dc.contributor.authorSzymczak, Wendy
dc.contributor.authorEngsbro, Anne Line
dc.contributor.authorLisby, Jan Gorm
dc.contributor.authorGranato, Paul
dc.contributor.authorLedeboer, Nathan
dc.contributor.authorGonzález-López, Juan José
dc.date.accessioned2025-09-22T10:04:47Z
dc.date.available2025-09-22T10:04:47Z
dc.date.issued2025-08
dc.identifier.citationSzymczak WA, Engsbro AL, Lisby JG, González-López JJ, Granato P, Ledeboer N, et al. Multicenter evaluation of the QIAstat-Dx Gastrointestinal Panel 2, a multiplex PCR platform for the diagnosis of acute gastroenteritis. J Clin Microbiol. 2025 Aug;63(8):e01983-24.
dc.identifier.issn1098-660X
dc.identifier.urihttp://hdl.handle.net/11351/13711
dc.descriptionDiarrhea; Ggastrointestinal infection; Syndromic testing
dc.description.abstractThe QIAstat-Dx Gastrointestinal Panel 2 (GI2 Panel) is a sample-to-answer multiplex PCR instrument that can detect 17 targets in a run time of about 80 minutes. The performance of the QIAstat-Dx GI2 Panel was evaluated by testing 1,939 prospective, 119 prospectively collected and then archived positive clinical samples and 750 retrospective clinical specimens across 13 sites in Europe and the United States. Specimens tested included bulk stool samples preserved in modified Cary-Blair transport medium. For most targets, results were compared to those of the FilmArray GI panel (13/17), and discordant results were adjudicated with a third assay. For the remaining targets (4/17), a composite comparator method was used, which included three comparator assays for each target. Before discordant resolution, the QIAstat-Dx GI2 Panel positive percent agreement (PPA) was 95% or greater for 5/17 targets (Campylobacter, E. coli O157, Cryptosporidium, Cyclospora cayetanensis, and Giardia lamblia) and 90% or greater for 11/17 targets: adenovirus F40/F41, astrovirus, norovirus GI/GII, rotavirus A, Plesiomonas shigelloides, enteropathogenic Escherichia coli, enterotoxigenic E. coli, Salmonella, Yersinia enterocolitica, Shiga-like toxin E. coli (STEC) stx1/stx2, and Shigella/enteroinvasive E. coli. No cases of Entamoeba histolytica were encountered during the clinical study. The negative percent agreement (NPA) was >98.9% for all QIAstat-Dx GI2 Panel targets. The three most common pathogens identified in single and co-infections were enteropathogenic E. coli (9.9%), Campylobacter (5.2%), and norovirus GI/GII (3.1%). In summary, this clinical study examined more than 2,800 samples from Europe and the U.S. using the QIAstat-Dx GI2 Panel and identified 90%-100% PPA and 99% NPA for its 17 targets.IMPORTANCEThe manuscript highlights the significance and impact of the QIAstat-Dx GI2 Panel, a sample-to-answer multiplex PCR instrument capable of detecting 17 targets in approximately 80 minutes. This comprehensive clinical study, conducted across 13 sites in Europe and the United States, evaluated the performance of the panel using over 2,800 clinical samples. The results demonstrate a high accuracy of the QIAstat-Dx GI2 panel, with a PPA equal to or higher than 90% for all targets and an NPA greater than 98.9% for all targets. These findings underscore the reliability and effectiveness of the GI2 panel in the rapid and precise detection of gastrointestinal pathogens, which is crucial for timely diagnosis and treatment of infections.
dc.language.isoeng
dc.publisherAmerican Society for Microbiology
dc.relation.ispartofseriesJournal of Clinical Microbiology;63(8)
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceScientia
dc.subjectGastroenteritis - Diagnòstic molecular
dc.subjectReacció en cadena de la polimerasa
dc.subject.meshGastroenteritis
dc.subject.mesh/diagnosis
dc.subject.meshMultiplex Polymerase Chain Reaction
dc.titleMulticenter evaluation of the QIAstat-Dx Gastrointestinal Panel 2, a multiplex PCR platform for the diagnosis of acute gastroenteritis
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1128/jcm.01983-24
dc.subject.decsgastroenteritis
dc.subject.decs/diagnóstico
dc.subject.decsreacción en cadena de la polimerasa múltiple
dc.relation.publishversionhttps://doi.org/10.1128/jcm.01983-24
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.audienceProfessionals
dc.contributor.organismesInstitut Català de la Salut
dc.contributor.authoraffiliation[Szymczak WA] Department of Pathology, Albert Einstein College of Medicine and Montefiore Medical Center, Bronx, New York, USA. [Engsbro AL, Lisby JG] Copenhagen University Hospital and Hvidovre, Copenhagen, Denmark. [González-López JJ] Servei de Microbiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. CIBER de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Community of Madrid, Spain. Departament de Genètica i de Microbiologia, Universitat Autònoma de Barcelona, Bellaterra, Spain. [Granato P] Laboratory Alliance of Central, Liverpool, New York, USA. [Ledeboer N] Department of Pathology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
dc.identifier.pmid40643259
dc.identifier.wos001527129600001
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record