Show simple item record

 
dc.contributorVall d'Hebron Barcelona Hospital Campus
dc.contributor.authorL'Imperio, Vincenzo
dc.contributor.authorCAPITOLI, GIULIA
dc.contributor.authorCazzaniga, Giorgio
dc.contributor.authorMannino, Mauro
dc.contributor.authorBono, Francesca
dc.contributor.authorSeminati, Davide
dc.contributor.authorTemprana Salvador, Jordi
dc.date.accessioned2025-10-22T12:27:57Z
dc.date.available2025-10-22T12:27:57Z
dc.date.issued2025-06
dc.identifier.citationL’Imperio V, Capitoli G, Cazzaniga G, Mannino M, Bono F, Seminati D, et al. The routine use of a digital tool for the tumor cell fraction quantification in molecular pathology: an international validation of QuANTUM. Pathologica. 2025 Jun;117(3):269–77.
dc.identifier.issn1591-951X
dc.identifier.urihttp://hdl.handle.net/11351/13917
dc.descriptionMolecular pathology; Non-small cell lung cancer; Tumor cell fraction
dc.description.abstractObjective: The absolute and relative quantification of tumor cell fraction (TCF) in tissue samples for molecular pathology testing is time-consuming and poorly reproducible. Methods: Here we report the results of an international survey on non-small cell lung cancer (NSCLC), validating the Qupath Analysis of Nuclei from Tumor to Uniform Molecular tests (QuANTUM) automated computational pipeline for TCF quantification. Results: The TCF obtained with QuANTUM is reliable, as demonstrated by the comparison with the manual counting of cells (ground truth, GT) in cell blocks, small biopsies and surgical specimens (overall correlation of 0.89). The visual evaluation of QuANTUM-processed images increased the pathologists' agreement with GT and QuANTUM of +0.16, +0.21, +0.09 and +0.17, +0.29, +0.21 across the three sample types, respectively. An overall increase in cases classified as containing ≥100 tumor cells for all sample types was noted after QuANTUM (from 75 cases, 63% to 96 cases, 80% among cell blocks, p = 0.003). Conclusions: QuANTUM is an easy-to-use and reliable tool for the TCF assessment and its employment significantly modifies the visual estimation by pathologists, improving the assessment of NSCLC cases for molecular analysis.
dc.language.isoeng
dc.publisherPacini Editore
dc.relation.ispartofseriesPathologica;117(3)
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceScientia
dc.subjectPulmons - Càncer - Diagnòstic
dc.subjectPulmons - Càncer - Aspectes moleculars
dc.subjectCitologia - Tècnica
dc.subject.meshCarcinoma, Non-Small-Cell Lung
dc.subject.mesh/diagnosis
dc.subject.meshCell Count
dc.subject.meshPathology, Molecular
dc.titleThe routine use of a digital tool for the tumor cell fraction quantification in molecular pathology: an international validation of QuANTUM
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.32074/1591-951X-1100
dc.subject.decscarcinoma de pulmón de células no pequeñas
dc.subject.decs/diagnóstico
dc.subject.decsrecuento de células
dc.subject.decspatología molecular
dc.relation.publishversionhttps://doi.org/10.32074/1591-951X-1100
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.audienceProfessionals
dc.contributor.organismesInstitut Català de la Salut
dc.contributor.authoraffiliation[L’Imperio V, Cazzaniga G, Mannino M, Bono F, Seminati D] Pathology, IRCCS Fondazione San Gerardo dei Tintori and Centro di Medicina Digitale, Dipartimento di Medicina e Chirurgia, University of Milano-Bicocca, Italy. [Capitoli G] Bicocca Bioinformatics Biostatistics and Bioimaging B4 Center, School of Medicine and Surgery, University of Milano-Bicocca, Monza, Italy. [Temprana-Salvador J] Servei d’Anatomia Patològica, Vall d’Hebron Hospital Universitari, Barcelona, Spain
dc.identifier.pmid40626670
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record