| dc.contributor | Vall d'Hebron Barcelona Hospital Campus |
| dc.contributor.author | Blackman, Daniel |
| dc.contributor.author | Gabbieri, Davide |
| dc.contributor.author | Kempfert, Jörg |
| dc.contributor.author | Laine, Mika |
| dc.contributor.author | García del Blanco, Bruno |
| dc.contributor.author | Mascherbauer, Julia |
| dc.date.accessioned | 2022-01-13T11:18:13Z |
| dc.date.available | 2022-01-13T11:18:13Z |
| dc.date.issued | 2021-12 |
| dc.identifier.citation | Blackman D, Gabbieri D, García Del Blanco B, Kempfert J, Laine M, Mascherbauer J, et al. Expert Consensus on Sizing and Positioning of SAPIEN 3/Ultra in Bicuspid Aortic Valves. Cardiol Ther. 2021 Dec;10:277–288. |
| dc.identifier.issn | 2193-6544 |
| dc.identifier.uri | https://hdl.handle.net/11351/6778 |
| dc.description | Bicuspid aortic valve; Bicuspid sizing; SAPIEN 3/Ultra |
| dc.description.abstract | Severe aortic stenosis patients with bicuspid anatomy have been excluded from the major transcatheter aortic valve replacement (TAVI) randomized clinical trials. As a result, there is no official recommendation on bicuspid TAVI. A panel of bicuspid experts was created to fill this gap. In this consensus statement, an algorithm is proposed to guide the choice of surgery or TAVI within this complex patient population, depending on aortic dilatation, age, surgical risk score, and anatomy. A step-by-step guide for sizing and positioning of the SAPIEN 3/Ultra TAVI bioprostheses is presented. Annular sizing remains the primary strategy in most bicuspid patients. However, some anatomies may require sizing at the supra-annular level, for which patients the panel recommends the circle method, a dedicated sizing and positioning approach for SAPIEN 3/Ultra. The consensus provides valuable pre-operative insights on the interactions between SAPIEN 3/Ultra and the bicuspid anatomy; understanding the valve–anatomy relationship is critical to avoid complications and to optimize outcomes for patients. |
| dc.language.iso | eng |
| dc.publisher | Springer |
| dc.relation.ispartofseries | Cardiology and Therapy;10 |
| dc.rights | Attribution-NonCommercial 4.0 International |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ |
| dc.source | Scientia |
| dc.subject | Medicina clínica - Presa de decisions |
| dc.subject | Vàlvula aòrtica - Estenosi - Cirurgia |
| dc.subject | Pròtesis valvulars cardíaques |
| dc.subject.mesh | Consensus |
| dc.subject.mesh | Aortic Valve Stenosis |
| dc.subject.mesh | /surgery |
| dc.subject.mesh | Heart Valve Prosthesis |
| dc.title | Expert Consensus on Sizing and Positioning of SAPIEN 3/Ultra in Bicuspid Aortic Valves |
| dc.type | info:eu-repo/semantics/article |
| dc.identifier.doi | 10.1007/s40119-021-00223-9 |
| dc.subject.decs | consenso |
| dc.subject.decs | estenosis de la válvula aórtica |
| dc.subject.decs | /cirugía |
| dc.subject.decs | prótesis valvulares cardíacas |
| dc.relation.publishversion | https://doi.org/10.1007/s40119-021-00223-9 |
| dc.type.version | info:eu-repo/semantics/publishedVersion |
| dc.audience | Professionals |
| dc.contributor.organismes | Institut Català de la Salut |
| dc.contributor.authoraffiliation | [Blackman D] Leeds Teaching Hospitals NHS Trust, Leeds, UK. [Gabbieri D] Hesperia Hospital, Modena, Italy. [García Del Blanco B] Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Kempfert J] German Heart Center Berlin, Berlin, Germany. [Laine M] Helsinki University Central Hospital, Helsinki, Finland. [Mascherbauer J] Karl Landsteiner University of Health Sciences, Krems, Austria |
| dc.identifier.pmid | 34081277 |
| dc.identifier.wos | 000657586200001 |
| dc.rights.accessrights | info:eu-repo/semantics/openAccess |