Show simple item record

 
dc.contributorVall d'Hebron Barcelona Hospital Campus
dc.contributor.authorPowell, Elizabeth
dc.contributor.authorSchneider, Torben
dc.contributor.authorBattiston, Marco
dc.contributor.authorToosy, Ahmed
dc.contributor.authorClayden, Jonathan D.
dc.contributor.authorGandini Wheeler-Kingshott, Claudia A.M.
dc.contributor.authorGrussu, Francesco
dc.date.accessioned2022-10-06T08:10:51Z
dc.date.available2022-10-06T08:10:51Z
dc.date.issued2022-11
dc.identifier.citationPowell E, Schneider T, Battiston M, Grussu F, Toosy A, Clayden JD, et al. SENSE EPI reconstruction with 2D phase error correction and channel-wise noise removal. Magn Reson Med. 2022 Nov;8(5):2157–66.
dc.identifier.issn1522-2594
dc.identifier.urihttps://hdl.handle.net/11351/8264
dc.descriptionNyquist ghost; Denoising; Diffusion
dc.description.abstractPurpose To develop a robust reconstruction pipeline for EPI data that enables 2D Nyquist phase error correction using sensitivity encoding without incurring major noise artifacts in low SNR data. Methods SENSE with 2D phase error correction (PEC-SENSE) was combined with channel-wise noise removal using Marcenko–Pastur principal component analysis (MPPCA) to simultaneously eliminate Nyquist ghost artifacts in EPI data and mitigate the noise amplification associated with phase correction using parallel imaging. The proposed pipeline (coined SPECTRE) was validated in phantom DW-EPI data using the accuracy and precision of diffusion metrics; ground truth values were obtained from data acquired with a spin echo readout. Results from the SPECTRE pipeline were compared against PEC-SENSE reconstructions with three alternate denoising strategies: (i) no denoising; (ii) denoising of magnitude data after image formation; (iii) denoising of complex data after image formation. SPECTRE was then tested using high -value (i.e., low SNR) diffusion data (up to  s/mm ) in four healthy subjects. Results Noise amplification associated with phase error correction incurred a 23% bias in phantom mean diffusivity (MD) measurements. Phantom MD estimates using the SPECTRE pipeline were within 8% of the ground truth value. In healthy volunteers, the SPECTRE pipeline visibly corrected Nyquist ghost artifacts and reduced associated noise amplification in high -value data. Conclusion The proposed reconstruction pipeline is effective in correcting low SNR data, and improves the accuracy and precision of derived diffusion metrics.
dc.language.isoeng
dc.publisherWiley
dc.relation.ispartofseriesMagnetic Resonance in Medicine;8(5)
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceScientia
dc.subjectImatges - Processament - Tècniques digitals
dc.subjectImatgeria mèdica
dc.subjectAlgorismes
dc.subject.meshImage Processing, Computer-Assisted
dc.subject.meshPhantoms, Imaging
dc.subject.meshArtifacts
dc.titleSENSE EPI reconstruction with 2D phase error correction and channel-wise noise removal
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.1002/mrm.29349
dc.subject.decsprocesamiento de imágenes asistido por ordenador
dc.subject.decsmodelos en imaginología
dc.subject.decsartefactos
dc.relation.publishversionhttps://doi.org/10.1002/mrm.29349
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.audienceProfessionals
dc.contributor.organismesInstitut Català de la Salut
dc.contributor.authoraffiliation[Powell E] Queen Square MS Centre, UCL Institute of Neurology, University College London, London, UK. Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, UK. [Schneider T] Philips Healthcare UK, Guildford, UK. [Battiston M, Toosy A] Queen Square MS Centre, UCL Institute of Neurology, University College London, London, UK. [Grussu F] Queen Square MS Centre, UCL Institute of Neurology, University College London, London, UK. Radiomics Group, Vall d’Hebron Institute of Oncology (VHIO), Barcelona, Spain. [Clayden JD] Developmental Imaging and Biophysics Section, Great Ormond Street Institute of Child Health, University College London, London, UK. [Gandini Wheeler-Kingshott CAM] Queen Square MS Centre, UCL Institute of Neurology, University College London, London, UK. Department of Brain and Behavioural Sciences, University of Pavia, Pavia, Italy. Brain MRI 3T Center, IRCCS Mondino Foundation, Pavia, Italy
dc.identifier.pmid35877787
dc.identifier.wos000829504900001
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record